Repair Systems — 03 — Facade & External Envelope

Sleeve torque-control mechanical wall tie

Supplier reference for sleeve torque-control mechanical remedial cavity wall ties for solid masonry facades on Class 2 strata buildings. Bolt-tightened sleeve expansion — torque is the key installation control. Solid masonry only. Compares Rawlplug, Würth, and Hilti HSA-R2 by grade, load data, and distribution.

3
Suppliers listed
Sleeve expansion
Fix type
Torque-controlled
Installation
Solid masonry
Substrate

Sleeve torque-control mechanical wall ties

Sleeve torque-control anchors use a bolt-tightened sleeve expansion mechanism — the bolt is torqued to a specified value to expand the sleeve against the bore hole walls. Consistent torque during installation is the key installation control parameter. Suitable for solid dense masonry only — never for hollow, perforated, or soft masonry. Structural engineer confirmation required for cavity wall tie replacement.

Supplier reference

3 of 3 suppliers
Sleeve Torque-Control Anchor

Rawlplug Stainless Sleeve Anchor (R-SL-A4)

Grade 316 stainless sleeve expansion anchor for structural masonry and cavity tie installation

Sleeve anchor316 SSTorque-controlRawlplugNational

Rawlplug R-SL-A4 is a Grade 316 stainless steel sleeve expansion anchor installed by drilling, inserting and tightening the bolt to expand the sleeve against the bore hole walls.

Sleeve Torque-Control Anchor

Würth Stainless Sleeve Anchor

Grade 316 stainless sleeve anchor for solid masonry anchoring with torque-controlled installation

Sleeve anchor316 SSTorque-controlWürthNational

Würth offers a range of Grade 316 stainless steel sleeve expansion anchors for structural masonry anchoring, suitable for remedial cavity wall tie installation in solid masonry substrates.

Sleeve Torque-Control Anchor

Hilti HSA-R2 Stainless Sleeve Anchor

Grade 316 stainless sleeve anchor with ETA approval and PROFIS design software support

HSA-R2316 SSETA approvedPROFISTorque-controlNational

Hilti HSA-R2 is a Grade 316 stainless sleeve anchor with ETA approval and PROFIS Anchor software design support for engineer specification in structural masonry anchoring.

Supplier comparison — sleeve torque-control mechanical ties
SupplierProductGradeInstallationLoad DataDistributionKey FeaturePrimary Use
Rawlplug AustraliaR-SL-A4 Sleeve Anchor316 (A4)Torque-controlledSupplier publishedNational (broad)Broad availabilityStandard solid masonry anchoring
Würth AustraliaWürth Stainless Sleeve316 SSTorque-controlledWürth publishedNational branchesTrade branch networkContractor-procured solid masonry
Hilti AustraliaHSA-R2 Sleeve Anchor316 (A4)Torque-controlledETA + PROFISNational directETA + design softwareEngineer-specified structural anchoring

Do not confuse sleeve torque-control ties with:

  • Wedge expansion ties — cone-wedge mechanism (not sleeve) — different geometry and edge distance requirements — listed on the wedge expansion tie page
  • Undercut expansion ties — high-load Hilti or Fischer undercut anchors with a keyed mechanical lock in an undercut profile — highest mechanical anchor capacity — listed on the undercut expansion tie page
  • Resin anchor ties — vinylester or epoxy chemical anchors — suitable for softer masonry where sleeve expansion would fail — listed on the cavity ties — resin anchor page
  • Helical grout-in ties — cementitious grouted helical ties — lower cost for standard residential masonry — listed on the cavity ties — helical page
  • Stainless steel through-bolts — bolting through the full masonry leaf is a different structural intervention and is not a cavity tie replacement system

Disclaimer

This page provides general technical information only. Sleeve torque-control ties are only suitable for solid, dense masonry. Tie type, diameter, embedment, and spacing must be confirmed by a structural engineer. Calibrated torque wrench is required — hand-tightening does not achieve design load.