Repair Systems — 04

Penetration flashing collar systems — pitched tiled roofs

Technical product reference for pre-formed and site-formed penetration flashing collar systems for round pipe and conduit penetrations through pitched tiled roofs. Covers Deks, Polyplas, and lead collar systems — size selection, pitch selection, and heritage applications.

5
Products listed
3
Brands covered
Pre-formed collar
Type
AS 1562 / NCC
Standard

What are penetration flashing collar systems?

Penetration flashing collar systems are pre-formed or site-formed weatherproofing elements installed where a round pipe or conduit penetrates through a pitched tiled roof. They provide the weather seal between the pipe OD and the surrounding tile course, preventing water ingress at the penetration point. The most common system in Australian residential and strata construction is the Deks D-1 range — a pre-formed EPDM collar with a polypropylene or aluminium base plate that seats between the tiles below and seals over the pipe above.

Product Reference

5 products — 3 brands — penetration flashing collar systems — scroll to view all

Filter by:
5 products — scroll for more
Deks Industries (Australian)

Deks D-1 Multi Flashing

Pre-formed EPDM penetration flashing collar

System Description

Deks D-1 Multi Flashing is the Australian industry standard pre-formed penetration flashing collar for round pipe and conduit penetrations through pitched tiled roofs. Manufactured by Deks Industries in Australia, it consists of a square aluminium or polymer base plate that sits on the roof deck below the tile level, with a flexible EPDM collar that seals around the pipe OD. The base plate is integrated into the roof sarking and tile course — the tile is cut to fit around the flashing base, and the EPDM collar is stretched over the pipe to create a watertight seal. D-1 is the standard Deks product for PVC plumbing vent pipes and electrical conduit penetrations through terracotta and concrete tiled roofs on Class 2 strata apartment buildings. Available in a range of sizes to suit pipe ODs from 13mm to 150mm. Confirm the pipe OD, roof pitch range, and tile profile with Deks technical before ordering to ensure the correct size and base plate configuration is specified.

Technical Properties

  • Pre-formed EPDM collar — factory-manufactured — no site forming required
  • Square base plate — aluminium or polymer depending on variant — integrates below tile course
  • Available for pipe OD 13mm to 150mm — confirm size range with current Deks product range

Limitations

  • Round collar only — not suitable for rectangular or square duct penetrations — use fabricated flashing for non-round penetrations
  • Pipe OD must be confirmed before ordering — ordering a collar one size too small or too large will not seal correctly
  • Not suitable for penetrations through flat or near-flat roof areas — use a plinth system for low-slope applications

PROCUREMENT SOURCES

Confirm suitability with the current manufacturer TDS before specifying or applying.

Deks Industries

Deks 45 Aluminium Flashing

Pre-formed aluminium-base EPDM penetration flashing collar

System Description

Deks 45 Aluminium Flashing is Deks Industries' penetration collar product incorporating an aluminium base plate rather than the polymer base plate used in the standard D-1 Multi Flashing. The aluminium base plate provides greater resistance to thermal movement on steep pitches and on concrete tile roofs where differential expansion between the tile and the flashing base is a concern. The EPDM collar is the same flexible sealing element as the D-1 range. The Deks 45 is the preferred product on concrete tile roofs, steeper pitched roofs, and on installations where the roof plumber requires a metal base plate for fixing or compatibility reasons. Confirm size, pitch compatibility, and current Deks 45 product range with Deks technical before ordering.

Technical Properties

  • Aluminium base plate — greater thermal stability than polymer base on concrete tile roofs and steep pitches
  • EPDM collar — flexible, weather-resistant sealing element around pipe OD
  • Pre-formed — no site forming required

Limitations

  • Confirm size range and pipe OD compatibility with Deks technical before ordering
  • Aluminium base plate is susceptible to dissimilar metal contact corrosion — avoid direct contact with copper or other incompatible metals in the roof assembly
  • Round collar only — not suitable for non-round penetrations

PROCUREMENT SOURCES

Confirm suitability with the current manufacturer TDS before specifying or applying.

Deks Industries

Deks Poly Multi-Pitch

Pre-formed multi-pitch polypropylene EPDM penetration flashing collar

System Description

Deks Poly Multi-Pitch is Deks Industries' polypropylene multi-pitch penetration flashing collar designed for situations where the roof pitch varies or is not standard, or where a single flashing product must be stocked for use across a range of roof pitches. The base plate is designed to be adjustable or configured at installation to match the roof pitch angle — confirm the adjustment mechanism and range from the current Deks Poly Multi-Pitch installation instructions. The EPDM collar provides the watertight seal around the pipe OD. The 0–45° pitch range makes this product suitable for use on very low-pitch tile roofs through to steep tiles pitches. Confirm pipe OD size range and current product name with Deks technical before specifying.

Technical Properties

  • Polypropylene base plate — adjustable pitch angle — suits pitches 0–45° (confirm from current TDS)
  • EPDM collar — flexible round pipe seal
  • Pre-formed — single product for variable pitch applications

Limitations

  • Confirm the actual pitch adjustment mechanism and valid pitch range from the current Deks installation instructions before specifying
  • Round EPDM collar only — not for non-round penetrations
  • Confirm pipe OD size range with Deks technical

PROCUREMENT SOURCES

Confirm suitability with the current manufacturer TDS before specifying or applying.

Polyplas

Polyplas Poly-I-Flash

Pre-formed EPDM penetration flashing collar — Australian-made

System Description

Polyplas Poly-I-Flash is an Australian-manufactured pre-formed polypropylene and EPDM penetration flashing collar, positioned as an alternative to the Deks D-1 range for round pipe and conduit penetrations through pitched tiled roofs. The product incorporates a polypropylene base plate and an EPDM collar element. Used for PVC plumbing vent pipes, electrical conduit, and similar round penetrations through terracotta and concrete tiled roof systems. Confirm pipe OD size range, roof pitch suitability, and installation requirements with Polyplas technical before ordering. Where Deks products are unavailable or where local supply of the Polyplas range is more convenient, Poly-I-Flash provides a comparable pre-formed collar solution.

Technical Properties

  • Pre-formed polypropylene base plate with EPDM round collar
  • Australian-manufactured — Polyplas
  • For round pipe and conduit penetrations through tiled roofs

Limitations

  • Confirm that the Polyplas Poly-I-Flash is interchangeable in application method and size with Deks products — do not assume equivalence without confirming from both TDS
  • Round collar only — not suitable for non-round penetrations
  • Confirm current product availability and distribution nationally with Polyplas before specifying

PROCUREMENT SOURCES

Confirm suitability with the current manufacturer TDS before specifying or applying.

Kempart Lead-Lined Collar

Lead-lined penetration flashing collar — heritage / specialist

System Description

Kempart lead-lined collar products are used for pipe penetrations through tiled roofs where a lead-dressed appearance is required, where heritage building conservation requirements specify lead flashing, or where the lead collar provides a superior dressing to the tile surface profile that a rigid pre-formed EPDM collar cannot achieve. Lead collars are dress-formed by the roof plumber on site, working the lead around the tile profile and pipe to create a weathertight seal. Lead has the advantage of being malleable and self-forming to complex tile profiles where a factory pre-formed polypropylene or EPDM base cannot sit flush. Used on heritage-listed buildings, high-specification restoration projects, and where a heritage conservation plan requires lead flashings. Confirm lead specification (code weight), minimum thickness, and detailing requirements with the heritage consultant or project specification before ordering.

Technical Properties

  • Lead-lined collar — malleable, dress-formed on site by roof plumber
  • Suitable for complex tile profiles where pre-formed EPDM collars cannot seat correctly
  • Heritage and conservation application — matches traditional lead flashing appearance

Limitations

  • Specialist product — requires skilled roof plumber experienced in lead dress-forming
  • Lead is a hazardous material — handling, cutting, and waste disposal must comply with safe work method statements and applicable state WHS regulations
  • Not a standard product for routine tiled roof penetration flashings — use Deks or Polyplas EPDM collar for standard non-heritage applications

PROCUREMENT SOURCES

Confirm suitability with the current manufacturer TDS before specifying or applying.

System Comparison

Side-by-side comparison of penetration flashing collar systems. Confirm all selections against current manufacturer TDS and confirm pipe OD and pitch before ordering.

ProductBrandBase materialCollar typePipe rangePitch rangeHeritageAustralian-made
D-1 Multi FlashingDeksPolymerEPDM round13mm–150mm ODStandard — confirm TDSNo Yes
Deks 45 AluminiumDeksAluminiumEPDM roundConfirm with DeksSteeper pitches — confirm TDSNo Yes
Poly Multi-PitchDeksPolypropyleneEPDM roundConfirm with Deks0–45° adjustableNo Yes
Poly-I-FlashPolyplasPolypropyleneEPDM roundConfirm with PolyplasStandard — confirm TDSNo Yes
Lead-Lined CollarKempartLeadLead dress-formedAny — dress-formed on siteAny — dress-formed on site YesConfirm

Do not confuse penetration flashing collars with:

  • Penetration plinth systems (listed on the Plinths page) — plinths are raised box enclosures for penetrations through flat or low-slope roof areas where a standard pre-formed collar cannot be used — not the same as a collar flashing through a pitched tile field
  • Sealant-only terminations — applying silicone sealant around a pipe penetration without a flashing collar is not an acceptable weatherproofing method for a tiled roof — a collar flashing must be installed
  • Valley flashings, step flashings, and counter flashings — these are flashing products for the junctions between roof planes and wall structures, not for pipe penetrations
  • Roofing collar foam kits — expanding foam collars are not an accepted weatherproofing method for external pipe penetrations through tiled roofs — a pre-formed EPDM collar is required

Disclaimer

Confirm pipe OD, roof pitch and tile profile with Deks or Polyplas technical before ordering. Final product selection must be confirmed against the current manufacturer technical data sheet, project specification, pipe size, roof pitch, and tile profile. Installed by a licensed roof plumber. Do not rely on this reference as a substitute for professional roofing consultant advice.