Repair Systems — 03 — Facade & External Envelope

Penetrating silane water repellent

Technical product reference for penetrating silane and silane-siloxane water repellent systems for masonry facade remediation on Australian Class 2 strata buildings. Penetrating silane treatments react with the masonry substrate to form a breathable hydrophobic barrier within the pore structure — reducing water absorption while allowing water vapour transmission. Applied as a supplementary treatment after all structural and repointing repairs have been completed; not a substitute for defective masonry repair.

3
Product types
Penetrating
Type
Invisible
Finish
AS 4858
Standard

Disclaimer

This page provides general technical information only. Silane water repellent selection, application rate and re-application interval must be confirmed against the project's masonry type, porosity and exposure conditions. Treatment is supplementary to structural repair — not a substitute for defective masonry remediation.